Posibles (futuros) drivers para Bombas

Esta es la lista de algunas Bombas que se van mencionando por ahí, y el grado de soporte a las mismas en cualquiera de los sistemas de Lazo cerrado y, a continuación, su situación respecto en AAPS. Al final hay alguna información, de lo que se requiere para que una bomba pueda ser utilizada para «Lazos Cerrados».

Bombas compatibles

Kaleido (Homepage)

Loop status: Pump is a Loop candidate, but protocol is unknown at the time. No interest in open source from the vendor.

Hardware requirement for AAPS: None. It seems to be BT enabled.

Tandem: t:slim X2 (Homepage)

Loop status: Not yet loopable.

While in the past company has decided not to allow their pumps to be controlled by external devices, it seems that last few years have been a game changer. Company decided to upgrade their t:slim X2 pump to be able to be controlled remotely (via t:connect app), which means that avenues are opened that we might be able to look forward to have control of pump via AAPS in the future. New pump firmware is planned to be released soon (this or next year, before their tubeless pump t:sport comes out). There are no details yet, what operations will be possible from t:connect (Bolus definitely, everything else unknown).

Hardware requirement for AAPS: None. It seems to be BT enabled.

Tandem: t:Mobi & t:slim X3 & t:Mobi Tubeless (Homepage)

Loop status: All 3 pumps will be Loop candidates.

Awaiting release of t:mobi in Europe (other two are not yet released anywhere). Development of AAPS t:mobi support has already started and should be available by end of 2025 (see more info on Discord).

Hardware requirement for AAPS: None. It seems to be BT enabled.

Willcare Insulin pump (Homepage)

Loop status: At the moment its not Loop candidate, but we were contacted by their staff and they interested in extending their pump to be loopable (at the moment I think its missing only get/set profile commands).

Hardware requirement for AAPS: None. It seems to be BT enabled.

Comments: Since company is interested in integration with AAPS, they might do implementation themselves.

Bombas que ya no se venden (las compañías ya no operan)

Animas Vibe

Animas Ping

Cellnovo

Accu-Chek Insight

Comments: End of support March 2025.

Bombas incompatibles

Medtronic Bluetooth

Comments: Medtronic withdrew.

Accu-Chek Solo

Comments: No community success in communicating with the Solo pump.

Ypsomed Pump

Comments: Ypso added very heavy 3rd party encryption.

Requisitos para que una bombas sea compatible

Prerequisite

  • La bomba debe disponer de algún tipo de control remoto. (BT, Radio frecuencia, etc)

  • El protocolo está documentado/hackeado/etc.

Minimal requirement

  • Establecer basales temporales

  • Obtener estado

  • Cancelar basales temporales

For oref1(SMB) or Bolusing:

  • Fijar Bolo

Good to have

  • Cancelar Bolo

  • Obtener perfil basal (casi un requisito)

  • Establecer Perfil Basal (recomendable)

  • Leer historial

Other (not required but good to have)

  • Suministrar bolos extendidos

  • Cancelar bolo extendido

  • Leer historial

  • Leer TDD

Other pumps support

If you have any other pumps you would like to see status on, please contact us on discord.