Διαμόρφωση

Depending on your settings you can open Config Builder through a tab at the top of AAPS” screen or through the hamburger menu.

Ανοίξτε το αρχείο Διαμόρφωσης (config builder)

The Config Builder is the tab where you turn the modular features on and off. In the picture below, the boxes on the left-hand side (A) allow you to select which modules you want activated, the boxes on the right-hand side (C) allow you to view these as a tab (E) in AAPS. In case the right box is not activated, you can reach the function by using the hamburger menu (D) on the top left of the screen. See Tab or hamburger menu below.

When there are additional settings available within the module, you can click on the cog wheel (B) which will take you to the specific settings within preferences.

Κουτάκια Διαμόρφωση και γρανάζι

Καρτέλα ή μενού Χάμπουργκερ

Με το πλαίσιο ελέγχου κάτω από το σύμβολο του ματιού μπορείτε να αποφασίσετε πώς να ανοίξετε την αντίστοιχη ενότητα του προγράμματος.

Καρτέλα ή μενού Χάμπουργκερ

Profile

This module can not be disabled as it is a core part of AAPS.

See Your AAPS Profile for a basic understanding of what goes inside your Profile.

Ινσουλίνη

Insulin type

Select the type of insulin you are using.

More information to understand the Insulin Profile as shown in AAPS here.

Insulin type differences

  • The options “Rapid-Acting Oref”, Ultra-Rapid Oref”, “Lyumjev” and “Free-Peak Oref” all have an exponential shape.

  • For “Rapid-Acting”, “Ultra-Rapid” and “Lyumjev” the DIA is the only variable you can adjust by yourself, the time to peak is fixed.

  • Free-Peak allows you to adjust both the DIA and the time to peak, and must only be used by advanced users who know the effects of these settings.

  • The insulin curve graph helps you to understand the different curves.

Γρήγορη δράση - Oref

Insulin type Rapid-Acting Oref

  • recommended for Humalog, Novolog and Novorapid

  • DIA = τουλάχιστον 5 ώρες

  • Μέγιστη. peak = 75 minutes after injection (fixed, not adjustable)

Έξτρα Γρήγορη δράση - Oref

Insulin type Ultra-Rapid Oref

  • recommended for FIASP

  • DIA = τουλάχιστον 5 ώρες

  • Μέγιστη. peak = 55 minutes after injection (fixed, not adjustable)

Lyumjev

Insulin type Lyumjev

  • special insulin profile for Lyumjev

  • DIA = τουλάχιστον 5 ώρες

  • Μέγιστη. peak = 45 minutes after injection (fixed, not adjustable)

Ελεύθερης κορυφής Oref

Insulin type Free Peak Oref

  • With the «Free Peak 0ref» profile you can individually enter the peak time. To do so click to cogwheel to enter advanced settings.

  • The DIA is automatically set to 5 hours if it is not specified higher in the profile.

  • This effect profile is recommended if an unbacked insulin or a mixture of different insulins is used.

Πηγή BG

Select the blood glucose source you are using. See BG Source page for more setup information.

Config Builder BG source

Smoothing

Smoothing

See Smoothing blood glucose data.

Pump

Select the pump you are using. See Compatible pumps page for more setup information.

Config Builder Pump selection

Ανίχνευση ευαισθησίας

Select the type of sensitivity detection. For more details of different designs please read on here. This will analyze historical data on the go and make adjustments if it recognizes that you are reacting more sensitively (or conversely, more resistant) to insulin than usual. More details about the Sensitivity algorithm can be read in the OpenAPS docs.

You can view your sensitivity on the homescreen in an additional graph. You can view your sensitivity on the homescreen by selecting SEN and watching the white line. Note, you need to be in Objective 8 in order to let Sensitivity Detection/Autosens automatically adjust the amount of insulin delivered. Before reaching that objective, the Autosens percentage / the line in your graph is displayed for information only.

Ρύθμιση απορρόφησης

If you use Oref1 with SMB you must change min_5m_carbimpact to 8. The value is only used during gaps in CGM readings or when physical activity «uses up» all the blood glucose rise that would otherwise cause AAPS to decay COB. At times when carb absorption can’t be dynamically worked out based on your blood’s reactions it inserts a default decay to your carbs. Basically, it is a failsafe.

APS

Select the desired APS algorithm for therapy adjustments. You can view the active detail of the chosen algorithm in the OpenAPS(OAPS) tab.

  • OpenAPS AMA

    • Advanced Meal Assist: older algorithm not recommended anymore.

    • In simple terms, the benefits are after you give yourself a meal bolus, the system can high-temp more quickly IF you enter carbs reliably.

  • OpenAPS SMB

    • Super Micro Bolus: most recent algorithm recommended for all users.

    • In contrast to AMA, SMB does not use temporary basal rates to control glucose levels, but mainly small Super Micro Boluses.

    • Note : It is recommended to use this algorithm from the beginning, even though you will not actually get SMBs delivered until Objective 9.

If switching from AMA to SMB algorithm, min_5m_carbimpact must be changed manually to 8 (default value for SMB) in Preferences > Sensitivity detection > Sensitivity Oref1 settings.

Κύκλωμα

This module should not be disabled as it is a core part of AAPS.

Constraints

Objectives

AAPS has a learning program (a series of objectives) that you have to fulfill step by step. This should guide you safely through setting up a closed loop system. It guarantees that you have set everything up correctly and understand what the system does exactly. This is the only way you can trust the system.

See Objectives page for more information.

Synchronization

In this section, you can choose if/where you want AAPS to send your data to.

NSClient or NSClientV3

Can be used as a reporting server and/or for remote monitoring, remote control.

See Synchronization with the reporting server to help you choose between NSClient (v1) and NSClientV3.

Tidepool

Can be used as a reporting server.

See Tidepool.

xDrip

Used to send data such as treatments to xDrip+.

Open Humans

See Open Humans.

Wear

Monitor and control AAPS using your Android WearOS watch (see page Watchfaces).

Samsung Tizen

Broadcast data to Samsung’s G-Watch Wear App (Tizen OS).

Garmin

Connection to Garmin device (Fenix, Edge…)

Θεραπείες

If you view the Treatments (Treat) tab, you can see the treatments that have been uploaded to nightscout. Should you wish to edit or delete an entry (e.g. you ate less carbs than you expected) then select “Remove” and enter the new value (change the time if necessary) through the carbs button on the home screen.

General

Σφαιρική Εικόνα

This is the main screen of AAPS and can not be disabled.

Show notes field in treatment dialogs

Choose if you want to have a notes field when entering treatments or not.

Φώτα κατάστασης

Choose if you want to have status lights on overview for cannula age, insulin age, sensor age, battery age, reservoir level or battery level. When warning level is reached, the color of the status light will switch to yellow. Critical age will show up in red.

Προηγμένες ρυθμίσεις

Deliver this part of bolus wizard result: When using SMB, many people do not meal-bolus 100% of needed insulin, but only a part of it (e.g. 75 %) and let the SMB with UAM (unattended meal detection) do the rest. In this setting, you can choose a default value for the percentage the bolus wizard should calculate with. If this setting is 75 % and you had to bolus 10u, the bolus wizard will propose a meal bolus of only 7.5 units.

Enable super bolus functionality in wizard (It is different from super micro bolus!): Use with caution and do not enable until you learn what it really does. Basically, the basal for the next two hours is added to the bolus and a two hour zero-temp activated. AAPS looping functions will be disabled - so use with care! If you use SMB AAPS looping functions will be disabled according to your settings in «Max minutes of basal to limit SMB to», if you do not use SMB looping functions will be disabled for two hours. Details on super bolus can be found here.

Ενέργειες

A tab offering multiple buttons to take actions in AAPS.

Αυτοματοποίηση

A tab for managing your Automations, starting at Objective 10.

Επικοινωνία με SMS

Allows remote caregivers to control some AAPS features via SMS, see SMS Commands for more setup information.

Φαγητό

Displays the food presets defined in the Nightscout food database, see Nightscout Readme for more setup information.

Note: Entries cannot be used in the AAPS calculator. (View only)

Wear

Monitor and control AAPS using your Android Wear watch (see page Watchfaces). Use settings (cog wheel) to define which variables should be considered when calculating bolus given though your watch (i.e. 15min trend, COB…).

If you want to bolus etc. from the watch then within «Wear settings» you need to enable «Controls from Watch».

Wear settings

Through Wear tab or hamburger menu (top left of screen, if tab is not displayed) you can

  • Resend all data. Might be helpful if watch was not connected for some time and you want to push the information to the watch.

  • Open settings on your watch directly from your phone.

Συντήρηση

Access this tab to export / import settings.

Διαμόρφωση

This current tab.